In development · Looking for pilot hospitals

Uroflowmetry at home, over several days

Open Uroflow is a home uroflowmeter that hospitals lend to patients. Patients measure every void at home; the urologist gets clinic style results for each one, and the trend across days.

The Open Uroflow prototype: a funnel over a jug standing on a weighing base with a lit button
The working prototype

The problems with one test in the clinic

A clinic uroflowmetry is a single void, on demand, in an unfamiliar room. Home measurement fixes what that cannot.

22%1

Many cannot void on demand

37 of 166 patients in a Belgian hospital's home uroflowmetry programme could not give a measurement in the hospital at all. At home they void when they need to.

1 in 41

Stress changes the result

About a quarter of the patients whose flow curve looked abnormal in the clinic had normal, bell shaped curves at home. And 32% of adults had a clinic Qmax below the lowest of their own home values.

Every void

Not one moment of one day

Flow changes from void to void and over the day. At home every void is measured, morning to night, over several days: 18 per patient on average in that programme.1

250 mL2

Volume matters

A man's maximum flow rises with the voided volume up to about 250 mL, then levels off. A single small void in the clinic cannot show where.

How it works

The jug stands on a precise scale. As urine arrives it gets heavier, and how fast it gets heavier is the flow.

1

Lend

The clinic gives the patient the device for a few days. It stands on the closed toilet lid, with nothing to install.

2

Measure

The patient presses the lit button and voids into the funnel as usual. The scale is read eleven times a second.

3

Review

Every void becomes a clinic style report with the International Continence Society's parameters, ready for the urologist.

Today's prototype records over USB. Bluetooth, the phone app and the clinician portal are in development.

21.9mL/sMaximum flow
304mLVoided volume
28.1sFlow time
10.8mL/sAverage flow
Time 00:00 Flow 0.0 mL/s Volume 0 mL

A synthetic example, analysed by our own software. Move across the chart to read it.

Built for urology clinics

Lent like a Holter monitor: the hospital owns the devices, patients take one home for a few days.

Follow up after surgery

Follow flow between visits after urethrotomy, urethroplasty or prostate surgery, and see a fall early.

Raw data, kept

Every reading is stored with its timestamp, so any void can be analysed again or audited later.

Made in Turkey

Designed and built in Turkey, for Turkish hospitals first and then the European Union.

Accurate where it matters

Clinical uroflowmeters are expected to read flow within 1 mL/s. These are the prototype's own bench figures.

0.03 mL/s

Signal noise

The scale's reading at rest, after the 2 second averaging the standard asks for.

12.7 ppm

Timing error

Each reading is timed by a crystal and checked against a reference clock.

< 1.2 mL/s

Centre or wall

A fluid simulation showed the stream's landing point in the jug makes no difference that matters.

A report the urologist can read

Each void becomes a one page PDF laid out like a clinic printout, made automatically.

  • Flow and volume curves on one time axis
  • Qmax, voided volume, flow time and curve shape, by ICS rules
  • Siroky nomograms with the result marked
A one page uroflowmetry report of the synthetic example

Run a pilot with us

We are looking for urology departments to pilot Open Uroflow with their patients, and for partners and investors who want home uroflowmetry in Turkey.

Write to us info@openuroflow.com

Still in development

Open Uroflow is not yet a CE marked medical device.

1. First-Year Experience of Managing Urology Patients With Home Uroflowmetry. JMIR Formative Research, 2023. PMC10618888 2. De Win G et al. The Added Value of Home-Uroflowmetry: Analyzing an Individual's VV-Qmax Curve and Inflection Point. Urology 2025;201:12-19.